To get the stage of realizing dreams of our employees! To build a happier, more united and much more skilled crew! To reach a mutual benefit of our prospects, suppliers, the society and ourselves for Insulating Flange , Tube Compression Fittings , Fried Dishes Pot , If you are interested in any of our items, please don't hesitate to contact us and take the first step to build up a successful business relationship.
ODM OEM Butt Weld Flange Factory Quotes – Flange Adaptor – DIKAI Detail:

Flange fittings are used in demanding applications due to their suitability to high pressure, shock, and vibration. They also allow for easy connections between hose and tube or pipe, as well as between rigid lines.

For tubing fittings that are larger than one inch in outside diameter, there are issues with both effective tightening and installation. Not only do these joints require larger wrenches, but workers must be able to apply the sufficient torque needed for proper tightening. Installation requires system designers to provide the space necessary for workers to be able to swing those larger-sized wrenches. If that wasn’t bad enough, the proper assembly of these fittings can be compromised due to the depleted strength and increased fatigue of workers trying to exert an applicable amount of torque. The split-flange fitting solves these issues.

Flange fittings have a high resistance to loosening, and can be assembled reasonably easily. These fittings are used in tight spaces. Currently, over 700 different sizes and configurations of split-flange fittings is available, making it very likely that one can be found for a specific application.

Split-flange fittings use rubber O-rings to seal joints and contain pressurized fluid. The O-ring sits in a groove on the flange, and then mates with a port’s flat surface. The flange is then attached to the port with four mounting bolts. The bolts tighten downward onto the clamps of the flange, thereby eliminating the need for large wrenches to connect the components of large-diameter tubing.

Elements of Split-Flange Fittings

Three elements must be in place for even the most basic of split-flange fittings. These are:

  1. An O-ring which fits into the flange’s end face groove;
  2. Two mating clamp halves with appropriate bolts for the connection between the split flange assembly and mating surface;
  3. A permanently connected flanged head, usually brazed or welded to the tube.

Tips for Effective Installation Using Split-Flange Fittings

When installing split-flange fittings, clean and smooth mating surfaces are a must. Otherwise, joints will leak. Inspecting joints for gouging, scratching and scoring can prevent future problems. It is important to note that rough surfaces will also contribute to the wear of O-rings.

In situations where perpendicular relationships are crucial, it must be ensured that each part meets the appropriate tolerances in order to prevent fluid from leaking through connections.

Although properly-designed split-flange assemblies see the flange shoulder protruding from 0.010 to 0.030 inches beyond the clamp face, no contact of clamp halves with the mating surface occurs.

Where the installation of flange connections is concerned, even torque must be applied on all four flange bolts. This will help avoid the creation of a gap which can cause o-ring extrusion once high pressure has been applied. As well, when tightening bolts, each must be tightened gradually and evenly using a cross pattern. It is not recommended to use air wrenches for this purpose, as pressure is not easily controlled and can result in the over-tightening of bolts.

Upward tipping of the flange can occur when only one of four bolts has been properly tightened. This can cause pinching of the O-ring. When this occurs, leaking at the joint is almost inevitable. Another scenario that can occur due to only one of four bolts being properly tightened is the bending of the bolts when all have been fully tightened. This happens when the flanges bend downward until they’ve bottomed on the port face, causing the bolts to bend outward. When bending of both flanges and bolts occurs, this can cause the flange to lift off the shoulder, causing joints to leak.


Product detail pictures:

ODM OEM Butt Weld Flange Factory Quotes –  Flange Adaptor  – DIKAI detail pictures


Related Product Guide:

We thinks what customers think, the urgency of urgency to act during the interests of a purchaser position of theory, allowing for much better good quality, lower processing costs, prices are extra reasonable, won the new and old buyers the support and affirmation for ODM OEM Butt Weld Flange Factory Quotes – Flange Adaptor – DIKAI , The product will supply to all over the world, such as: Jamaica, Juventus, Oman, All our staffs believe that: Quality builds today and service creates future. We know that good quality and the best service are the only way for us to achieve our customers and to achieve ourselves too. We welcome customers all over the word to contact us for future business relationships. Our products are the best. Once Selected, Perfect Forever!
  • This company has the idea of "better quality, lower processing costs, prices are more reasonable", so they have competitive product quality and price, that's the main reason we chose to cooperate.
    5 Stars By Mark from UAE - 2018.06.18 19:26
    The goods are very perfect and the company sales manager is warmful, we will come to this company to purchase next time.
    5 Stars By Moira from Amman - 2018.09.21 11:01
    Write your message here and send it to us