That has a positive and progressive attitude to customer's interest, our organization consistently improves our products quality to satisfy the demands of shoppers and further focuses on safety, reliability, environmental specifications, and innovation of Reducing Flexible Coupling , Automatic Roll Grooved Machine , 2 In Coupling , We invites you and your enterprise to thrive together with us and share a bright future in global market.
Wholesale China Flange Manufacturer Factory Quotes – Flange Adaptor – DIKAI Detail:

Flange fittings are used in demanding applications due to their suitability to high pressure, shock, and vibration. They also allow for easy connections between hose and tube or pipe, as well as between rigid lines.

For tubing fittings that are larger than one inch in outside diameter, there are issues with both effective tightening and installation. Not only do these joints require larger wrenches, but workers must be able to apply the sufficient torque needed for proper tightening. Installation requires system designers to provide the space necessary for workers to be able to swing those larger-sized wrenches. If that wasn’t bad enough, the proper assembly of these fittings can be compromised due to the depleted strength and increased fatigue of workers trying to exert an applicable amount of torque. The split-flange fitting solves these issues.

Flange fittings have a high resistance to loosening, and can be assembled reasonably easily. These fittings are used in tight spaces. Currently, over 700 different sizes and configurations of split-flange fittings is available, making it very likely that one can be found for a specific application.

Split-flange fittings use rubber O-rings to seal joints and contain pressurized fluid. The O-ring sits in a groove on the flange, and then mates with a port’s flat surface. The flange is then attached to the port with four mounting bolts. The bolts tighten downward onto the clamps of the flange, thereby eliminating the need for large wrenches to connect the components of large-diameter tubing.

Elements of Split-Flange Fittings

Three elements must be in place for even the most basic of split-flange fittings. These are:

  1. An O-ring which fits into the flange’s end face groove;
  2. Two mating clamp halves with appropriate bolts for the connection between the split flange assembly and mating surface;
  3. A permanently connected flanged head, usually brazed or welded to the tube.

Tips for Effective Installation Using Split-Flange Fittings

When installing split-flange fittings, clean and smooth mating surfaces are a must. Otherwise, joints will leak. Inspecting joints for gouging, scratching and scoring can prevent future problems. It is important to note that rough surfaces will also contribute to the wear of O-rings.

In situations where perpendicular relationships are crucial, it must be ensured that each part meets the appropriate tolerances in order to prevent fluid from leaking through connections.

Although properly-designed split-flange assemblies see the flange shoulder protruding from 0.010 to 0.030 inches beyond the clamp face, no contact of clamp halves with the mating surface occurs.

Where the installation of flange connections is concerned, even torque must be applied on all four flange bolts. This will help avoid the creation of a gap which can cause o-ring extrusion once high pressure has been applied. As well, when tightening bolts, each must be tightened gradually and evenly using a cross pattern. It is not recommended to use air wrenches for this purpose, as pressure is not easily controlled and can result in the over-tightening of bolts.

Upward tipping of the flange can occur when only one of four bolts has been properly tightened. This can cause pinching of the O-ring. When this occurs, leaking at the joint is almost inevitable. Another scenario that can occur due to only one of four bolts being properly tightened is the bending of the bolts when all have been fully tightened. This happens when the flanges bend downward until they’ve bottomed on the port face, causing the bolts to bend outward. When bending of both flanges and bolts occurs, this can cause the flange to lift off the shoulder, causing joints to leak.


Product detail pictures:

Wholesale China Flange Manufacturer Factory Quotes –  Flange Adaptor  – DIKAI detail pictures


Related Product Guide:

Our eternal pursuits are the attitude of "regard the market, regard the custom, regard the science" plus the theory of "quality the basic, have faith in the main and management the advanced" for Wholesale China Flange Manufacturer Factory Quotes – Flange Adaptor – DIKAI , The product will supply to all over the world, such as: UK, Madrid, Porto, Till now, the goods list has been updated regularly and attracted clients from around the globe. Detailed facts is often obtained in our web-site and you'll be served with premium quality consultant service by our after-sale group. They are going to help you get comprehensive acknowledge about our products and make a satisfied negotiation. Company go to to our factory in Brazil is also welcome at any time. Hope to obtain your inquiries for any pleased co-operation.
  • The factory workers have a good team spirit, so we received high quality products fast, in addition, the price is also appropriate, this is a very good and reliable Chinese manufacturers.
    5 Stars By Edwina from Colombia - 2017.06.19 13:51
    The sales manager has a good English level and skilled professional knowledge, we have a good communication. He is a warm and cheerful man, we have a pleasant cooperation and we became very good friends in private.
    5 Stars By Christian from Los Angeles - 2017.10.23 10:29
    Write your message here and send it to us